PW333X-2/3 Channel Power Meter With 65A Direct Input

Catalogue

  • Hioki benchtop power meters and power analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The PW3337 series measure power on the full range of electrical equipment, from single-phase devices such as battery-driven devices and household electronics to industrial use and three-phase electrical equipment over 3 input channels. The power meters provide coverage from DC to inverter frequencies with support for voltages up to 1000 V and direct-input currents of up to 65 A, and can also measure currents of up to 5000 A using an optional current sensor.

Measurement lines

Single-phase 2-wires, single-phase 3-wires, 3-phase 3-wires, 3-phase 4-wires (voltage / current measurement range set for each wiring mode)

Input resistance (50/60 Hz)

[Voltage] 2 MΩ, [Current] 1 mΩ or less (direct input)

Display refresh rate

5 times/s to 20 seconds (depends on average times settings)

Frequency characteristics

DC, 0.1 Hz to 100 kHz

Interfaces

RS-232C / LAN standard, (-01/-03 model also includes GP-IB)

Measurement items

Voltage, Current, Active power, Apparent power, Reactive power, Power factor, Phase angle, Frequency, Efficiency, Current integration, Active power integration, Integrated time, Voltage waveform peak value, Current waveform peak value, Voltage crest factor, Current crest factor, Time average current, Time average active power, Voltage ripple factor, Current ripple factor

Harmonic parameters

Synchronization frequency range: 10 Hz to 640 Hz, Analysis order up to 50th Harmonic voltage RMS value, Harmonic current RMS value, Harmonic active power, Total harmonic voltage distortion, Total harmonic current distortion, Voltage fundamental waveform, Current fundamental waveform, Active power fundamental waveform, Apparent power fundamental waveform, Reactive power fundamental waveform, Power factor fundamental waveform (displacement power factor), Voltage current phase difference fundamenta

Measurement range (*1)

[Voltage] 0.15 V to 1000 V AC/DC [Current] Direct input: 2 mA to 65 A AC/DC For AC/DC measurement using the CT6877A as an example: 4 A to 2000 A AC/DC (typical accuracy ±0.348%) For AC measurement using the CT9667-01 as an example: 10 A to 5000 A AC (typical accuracy ±2.6%)

Integration measurement (Integration time up to 10,000 hours)

[Current] No.of displayed digits: 6 digits (from 0.00000 mAh, Polarity-independent integration and Sum value) [Active power] No.of displayed digits: 6 digits (from 0.00000 mWh, Polarity-independent integration and Sum value)

Basic accuracy (Active power)

±0.1% rdg. ±0.1% f.s. (DC) ±0.1% rdg. ±0.05% f.s. (45 Hz to 66 Hz, at Input < 50% f.s.) ±0.15% rdg. (45 Hz to 66 Hz, at 50% f.s. ≤ Input)

D/A output (-02/-03 model only)

16 channels (selectable from following items), Level output DC ±2 V, Waveform output 1 V f.s. Level output, instantaneous waveform output (voltage, current, active power) Level output (apparent power, reactive power, power factor, or other) High-speed active power level output

Functions

[Rectification method] AC+DC, AC+DC Umn, AC, DC, FND, Auto-range, Average, VT or CT ratio settings, Synchronized control, MAX/MIN, or other functions

Power supply

100 to 240 V AC, 50/60 Hz, 40 VA max.

Dimensions and mass

305 mm (12.01 in) W × 132 mm (5.20 in) H × 256 mm (10.08 in) D, 5.6 kg (197.5 oz)

Included accessories

Instruction manual × 1, Measurement guide × 1, Power cord × 1